How Do I Change the Oil in My Portable Generator?

« Go Back
Fields
How Do I Change the Oil in My Portable Generator?
How-Do-I-Change-the-Oil-in-My-Portable-Generator
Content

Read the manual thoroughly and understand all of the instructions, cautions, and warnings before using this equipment. If any section of the manual is not understood, contact your nearest authorized dealer, or contact Generac Customer Service at 1-888-436-3722 (1-888-GENERAC), or www.generac.com with any questions or concerns.  

How to change the oil in a portable generator

This article provides a general step-by-step guide to changing the oil in a portable generator. For specific unit requirements, please take a look at the owner's manual maintenance section. To obtain a copy of the owner's manual see Where can I download a user manual for my Generac portable generator?
 

Environment

This article applies to most portable generators. Always reference the user manual for your specific generator model for the most accurate information regarding oil change procedures and maintenance.

 

Video guide to changing a portable generator's oil

This video shows the GP8000E; however, owners should always refer to their specific generator's user manual for appropriate oil change intervals and procedures. The I Can’t Find My Original Owner’s Manual for My Portable Generator, How Can I Get Another Copy? article provides instructions for locating a Generac portable generator user manual.




Most portable generators require an oil change within the first 30 hours, but some smaller generators will require it earlier.

 

Note: Change the oil more frequently when using portable generators in extreme, dirty, or dusty conditions or in extremely hot weather. 

Step-by-step procedure 

The steps below outline a general process. Always review your generator's user manual for specific steps that may be unique to your generator model. For example, portable units with an OHVI engine require an oil filter. Use the product lookup tool on Generac.com to find your generator's user manual.

 

1. Run the generator for a few minutes to allow the oil to heat up and become more viscous with the engine's heat. 
2. Wait until the engine is cool enough to be touched.
3. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact the spark plug. 
4. Clean the area around the oil fill and oil drain plug. 
5. Remove the oil fill cap/dipstick.
6. Remove the oil drain plug and drain the oil completely into a suitable container. 
7. Install the oil drain plug and tighten it securely. 
8. Refill the crankcase with oil to the Full line (H). Refrain from overfilling.
9. Install the oil fill cap/dipstick and hand-tighten. 
10. Wipe up any spilled oil.
11. Properly dispose of oil following all applicable regulations. 

 

Drain bolt size by engine size: 

  • 173cc, 196cc, 212cc Drain bolts are M10-1.25 thread pitch
  • 389cc, 420cc, 459cc Drain bolts are M12-1.5 thread pitch

Note: Please return used oil to collection centers. 
 