Read the manual thoroughly and understand all of the instructions, cautions, and warnings before using this equipment. If any section of the manual is not understood, contact your nearest authorized dealer, or contact Generac Customer Service at 1-888-436-3722 (1-888-GENERAC), or www.generac.com with any questions or concerns.
Generac cold weather accessories
Environment
This article applies to Generac cold weather accessories designed for specific air-cooled and liquid-cooled home standby generators.
- Generac Next Generation Series 10–28 kW air-cooled standby generators.
- Generac Guardian Series 10–26 kW air-cooled standby generators (2017 to present).
- This article partially applies to the 7.5 kW PowerPact. PowerPact cold weather accessories are provided in the Cold Weather Kit (part number 6808-1).
Accessory part numbers can vary by product series. See each section for series-specific details.
Overview
Generac cold weather accessories are designed to enhance reliability and performance in cold climates by reducing the impact of low temperatures on critical components.
Contents
What types of cold weather accessories are available?
Air-cooled home standby cold weather accessories
Battery pad warmer

Purpose: Helps maintain battery temperature to support starting performance in extreme cold.
Why it's helpful:
-
- Batteries can lose efficiency or freeze in extreme cold, reducing starting power.
- Adding warmth supports reliable starts and can extend battery usability in cold weather.
- Compatible with units manufactured from 2008–present.
- Not necessary for AGM-style batteries when used with Guardian-series generators. These are recommended for use with AGM batteries for Next Generation models.
- Recommended for regions regularly experiencing temperatures below 0 °F.
- Part numbers: G0071010 (Guardian Series), G0072110 (Next Generation Series). For 7.5 kW PowerPact units, this item is included in the Cold Weather Kit (part number 6808-1).
Oil filter warmer (oil warmer)

Purpose: Helps keep engine oil flowing by reducing the chance of thickening around the oil filter in cold temperatures.
Why it's helpful:
-
- In freezing conditions, engine oil can become more viscous, making circulation harder.
- A warm oil filter supports smoother oil flow, reducing engine strain during starts.
- Compatible with units manufactured from 2008–present.
- Part numbers: G0071020 (Guardian Series), G0071021 (Next Generation Series).
Breather warmer

Purpose: Helps prevent ice formation in the breather system and maintains proper airflow/venting.
Why it's helpful:
-
- Moisture can freeze in sub-zero temperatures, causing blockages and performance issues.
- Added heat reduces ice buildup risk to help maintain airflow in extreme cold.
- Suitable for extremely cold climates where heavy icing occurs.
- Compatible with units manufactured from 2008–present.
- Part numbers: G0071030 (Guardian Series), G0071032 (Next Generation Series).
Liquid-cooled home standby cold weather accessories
Consult the unit’s service documentation or an IASD for liquid-cooled accessory options and compatibility.
Who are these accessories recommended for?
- Regions where winter temperatures routinely fall below 32 °F.
- Extreme-cold areas with regular sub-zero conditions or heavy icing.
Who can install the cold weather kit?
- In addition to installing a battery with higher CCA (cold cranking amps), cold weather accessories are recommended in regions where temperatures regularly fall below 32 °F (0 °C).
- When installing any cold weather item, replace engine oil with either Generac 5W-20 full synthetic oil or 5W-30 full synthetic oil.
- Connection points vary by model. Consult the owner’s manual for complete instructions or use the dealer locator to contact a Generac service dealer for installation help.
- Accessory thermostats typically switch ON at 40 °F (4 °C) and OFF at 55 °F (13 °C).
Why are these accessories helpful in cold weather?
- Improve starting performance and reduce mechanical strain in low temperatures.
- Help maintain proper lubrication, airflow, and battery readiness.
Which units are compatible with cold weather kits?
Compatibility varies by model, production year, and controller. Connections may differ for older, non-Nexus/Evolution panels. For controller-specific or legacy model guidance, contact an IASD or Generac Customer Support (888-436-3722).
AGM batteries and battery pad warmers
Battery warmers are not recommended with AGM-style batteries when used with Guardian-series units. When used with Next Generation standby generators, battery pad warmers for AGM-style batteries are recommended.
Where can I purchase a cold weather kit?
- Use the dealer locator to find a local Generac dealer.
- Ordertree and other retailers may carry individual accessories by part number.